Skip to main content

HistoCore NANOCUT R - Automated Research & Special Applications Rotary Microtome

14052458261

Discover New Breakthroughs with an Enhanced Level of Precision and Versatility

When your microtomy involves diverse samples in order to discover new breakthroughs in your research projects, then NANOCUT R is the optimal solution for you. The new generation of microtomes from Leica Biosystems is built upon our 145+ year heritage of market-leading microtome design. From biomedical research to industrial applications, NANOCUT R can cut virtually anything you put in front of it.

  • Cut sections that can be prepared for analysis in light microscopy and electron microscopy - down to 250nm (0.25µm, semi-thin).
  • Preserve sample integrity when performing semi-thin sectioning with the Special Spindle and expanded Slow Speed Adjustment.
  • Precisely stop the sample in the object head’s optimal position for photo-capture of the cut sample surface when running 3-dimensional reconstruction programs.*
Contact us to get a quote. Call 050-1807-0257 to speak with a representative.

*Source for Featured 3D Reconstruction Content: IGBMC, PHENOMIN, iCS

For Research Use Only. Not for use in diagnostic procedures.

Product Features

Precise and Consistent Semi-Thin Sectioning

Avoid destruction of samples with the Special Spindle and expanded Slow Speed Adjustment capabilities which allow you to produce consistent semi-thin sections down to 250nm.

Image
HistoCore NANOCUT R Hero Front Knife Holder GD

Tackle the Toughest Materials with a Wide Range of Accessories

Leverage a wide range of accessories available to the NANOCUT R, including holders for disposable steel and tungsten carbide blades, reusable knives, and a special holder for glass and diamond knives.

Image
HistoCore NANOCUT R Hero Front Knife Holder NZ

3D Reconstruction Stacking Technique

Precisely stop the sample in the object head's optimal position for photo-capture of the cut sample surface when running 3-dimensional reconstruction programs.

Image
csm_3d-reconstruction

Precision-Orientation System

Always get back to a 0-position home on the microtome, regardless of how you (or another tech) have changed the instrument's orientation.

Image
HistoCore_NANOCUT_R_Knife_Holder_E_TC_Orientation

Force Balance System

Minimize the risk of injury to the operator or specimen by an unbalanced object head.

Product Specifications

GENERAL

Type: Motorized
Nominal Supply Voltage: 100 / 120 / 230 / 240 V AC
Nominal Frequency: 50/60 Hz
Maximum Power Consumption: 100 VA
Protection Class: I
Power Fuses: 2 x T3,15 AL, 250V
Pollution Degree: 2
Overvoltage Category: II
Maximum Heat Emission: 340 J/s
Operating Temperature Range: +18°C to +30°C
Temperature Range During Storage: +5°C to +50°C
Relative Humidity During Operation: 20% to Max. 80% Non-Condensing
Relative Humidity During Storage: 10% to Max. 85% Non-Condensing

DIMENSIONS & WEIGHT

BASIC INSTRUMENT  
Width (including handwheel): 415 mm
Depth (including waste tray): 620 mm
Height (without top tray): 295 mm
Weight (without accessories): Approx. 40 kg
CONTROL PANEL  
Type: Separate control panel & in-housing integrated instrument control panel
Width: 119 mm
Depth: 193 mm
Height: 50 mm
Height (in inclined position): 81 mm
Weight (net): 0.6 kg

MICROTOME PERFORMANCE SPECS

Specimen Feed: approx. 24 mm ±1 mm
Vertical Stroke: 70 mm ±1 mm
  Large Standard Clamp: 55 x 50 x 30 mm

Super Cassette Clamp: 68 x 48 x 15 mm
Motorized Sectioning Speeds: 0 - 195 mm/s ±10%
SPECIMEN RETRACTION  
In Manual Sectioning Mode: 5 - 50 µm (in 5 µm increments); can be turned off
In Motorized Sectioning Mode: Speed-Dependent; can be turned off
SPECIMEN ORIENTATION  
Horizontal: ± 8°
Vertical: ± 8°
SECTION THICKNESS SETTINGS  
Range: 0.25 - 50 µm
Setting Values: 0.25 - 0.5 µm (in 0.25 µm increments)
  0.5 - 5 µm (in 0.5 µm increments)
  5 - 20 µm (in 1 µm increments)
  20 - 50 µm (in 5 µm increments)
TRIMMING SECTION THICKNESS SETTINGS:  
Range: 1 - 300 µm
Setting Values: 1 - 10 µm (in 1 µm increments)
  10 - 20 µm (in 2 µm increments)
  20 - 50 µm (in 5 µm increments)
  50 - 100 µm (in 10 µm increments)
  100 - 300 µm (in 50 µm increments)

ADDITIONAL SPECIFICATIONS

Handwheel Balance System:
Handwheel Lock / Brake: 2 Mechanical Locks, 1 Electronic Brake
Safety Hand Wheel: Handle can be Centered
WASTE TRAY  
Type Standard Waste Tray
Waste Tray Volume 1400 ml
SELECTABLE CUTTING MODES  
Rock Mode: - with activated retraction
Single Mode:
Continuous Mode:
Step Mode:
Program Mode:
BLADE HOLDER  
Type: Semi-Thin Sectioning - Knife Holder GD

Resin Sectioning - Knife Holder NZ or Knife Holder E-TC

Paraffin Sectioning: 2-in-1 Blade Holder E
North-South Movement: ± 24 mm
East-West Movement: 3 Positions
Lateral Displacement Function: via knife holder
CE
clamping top
SPECIAL FEATURES  
Remaining Feed Indicator Visual and Acoustical
Section Counter
Section Thickness Totalizer
Memory Position
Special Spindle for Precise Semi-Thin Sectioning
Expanded Slow Speed Adjustment for Precise Semi-Thin Sectioning
Precise 3D Object Head Stop Position

Quick Compare Chart

  • Image
    HistoCore BIOCUT R

  • Image
    HistoCore MULTICUT-R-600x420

  • Image
    HistoCore AUTOCUT R

  • Image
    HistoCore NANOCUT R

Product

Image
HistoCore BIOCUT R

HistoCore BIOCUT R

View product

Image
HistoCore MULTICUT-R-600x420

HistoCore MULTICUT R

View product

Image
HistoCore AUTOCUT R

HistoCore AUTOCUT R

View product

Image
HistoCore NANOCUT R

HistoCore NANOCUT R

Currently viewing

Type Mechanical Semi-Motorized Motorized Motorized
Precision-Orientation System        
Force Balance System        
2-in-1 Blade Holder        
Specimen Cooling Option with RM CoolClamp        
Standard Waste Tray        
Silent Retraction        
Personalized Coarse Feed Wheel        
Fast Homing        
Memory Position        
Electronic Brake        
Special Spindle for Precise Semi-Thin Sectioning        
Expanded Slow Speed Adjustment for Precise Semi-Thin Sectioning        
Precise 3D Object Head Stop Position        

Downloads

IFU

Certificate

Configurations

Basic Instrument (14052458261)

  • Rotary microtome with Automated and Manual Modes
  • Automatic Electronic Brake
  • Special Spindle and expanded slow speed adjustment capabilities allows accurate specimen feeding for semi-thin sections of 250 nm
  • Precise 3D object head stop position allows for taking pictures of the cut specimen surface after each section to enable 3D reconstruction
  • Includes standard waste tray and top tray

HistoCore NANOCUT R Parts/Accessories

HistoCore NANOCUT R Publications