![Knowledge-Pathway-Hero-image Knowledge-Pathway-Hero-image](/themes/contrib/lbs-drupal-theme/images/default/common/720_Knowledge-Pathway-Hero-image.jpeg)
Steps to Better Specimen Collection and Transport
![Geoffrey Rolls](/sites/default/files/styles/square/public/media_image-file/2020-12/Geoffrey-Rolls.jpg.webp?itok=nrXJdZVf)
From patient to pathologist, preparing tissue specimens for histological examination requires care, skill and sound procedures. This guide provides practical advice on best practice techniques and simple ways to avoid common errors.
Tips for better specimen collection and transport are highlighted in this guide. We hope each step provides a valuable reminder of good histology practice and helps with troubleshooting when unacceptable results do occur.
Want to see all 101 Steps to Better Histology?
Download 101 Steps to Better Histology now!
Avoid Mechanical Trauma
Tissue is removed gently to avoid trauma to the specimen caused by crushing or tearing. This applies both during surgery and during any further dissection that may be required of a fresh specimen.
Specimen is damaged before fixation by crushing or tearing during removal.
![Typical crush artifact is shown in this section of lymphoid tissue. It is characterized by dark, distorted cell nuclei, some of which are extremely elongated and intensely basophilic. Typical crush artifact is shown in this section of lymphoid tissue. It is characterized by dark, distorted cell nuclei, some of which are extremely elongated and intensely basophilic.](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/Step-01-Artefact-crush_400x300.jpg?itok=5D-fMhz7)
Prevent Specimen Drying
Specimen is not allowed to dry out prior to fixation. If immediate fixation is not practicable, gauze moistened with saline can be used to prevent this.
Specimen is left on absorbent surface for some time prior to fixation.
![This fresh specimen has just been removed from a patient during surgery. Because it is resting on an absorbent surface and the theater is quite warm it will rapidly dry out unless it is immediately placed in fixative.](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/Step_02_Fresh_specimen_drying_out.jpg?itok=i1ugqRkp)
Avoid Heat Damage
As far as possible avoid local heat damage to specimens (some damage by cautery may be unavoidable).
Any unnecessary local heat applied to tissue will cause damage. Fresh tissue is particularly susceptible.
![A localized area at the edge of this breast specimen exhibits strong acidophilia with a loss of nuclear and cytoplasmic detail. These effects are the result of heat damage caused when cautery was used during the removal of the specimen. Adjacent glandular](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/csm_Step_03_Artefact_heat_damage_4706061fc6.jpg?itok=SIG9UvjK)
Avoid Chemical Damage
Avoid contaminating fresh specimens with foreign chemicals or substances such as disinfectants.
The surface of unfixed tissue can be easily penetrated and damaged by foreign reagents or substances.
![Monsel’s solution (ferric subsulfate solution) is a topical hemostatic agent used to control bleeding following mucosal biopsy. It causes coagulation and necrosis of the mucosal surface. If it is applied before a biopsy is taken it causes local basophilia](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/csm_AB_d8dad1cb9d.jpg?itok=Zpa4IBLb)
Label Specimens Properly
Each specimen should be properly identified, and all details recorded as soon as possible.
Recording of specimen details is delayed and the information provided is incomplete.
![Specimens with incomplete labels such as these, should not be accepted by a laboratory. A procedure must be in place to deal with specimens that arrive at the lab inadequately labeled or accompanied by incomplete or inconsistent documentation.](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/csm_Step_05_Incomplete_labels_0e1e0ea613.jpg?itok=z21DKcvC)
Ensure Prompt Fixation
Fixation is always carried out promptly. If it is necessary that a specimen remains unfixed for a short period of time, it should be refrigerated at 4 °C.
Fixation is delayed (degeneration of tissue elements commences as soon as the specimen is deprived of a blood supply).
![ensure prompt fixation](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/Step-6-Ensure-Prompt-Fixation.jpg?itok=ferLGHNg)
Use Sufficient Fixative and a Suitable Container
An adequate volume of fixative (ratio of at least 20:1) is used in a container of an appropriate size. This avoids distortion of the fresh specimen and ensures good quality fixation.
Specimens are sometimes squashed into a small container with insufficient fixative to cover the specimen surface.
![Use Sufficient Fixative and a Suitable Container](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/csm_Step_07_Large_spec_in_small_container_70fda3189e.jpg?itok=JCX3fXxI)
Check Fixative pH
The fixative is of high quality and at the optimal pH.
The fixative is of poor quality and unknown pH. If formalin is used at acid pH it rapidly produces “formalin pigment” by reaction with hemoglobin. Near neutral solutions will still produce the pigment but much more slowly. In good histological preparations, formalin pigment should be removed prior to staining.
![Check fixative pH](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/Step-8-Check-Fixative-pH.jpg?itok=25isQbXi)
Expedite Large Specimen Fixation
The specimen dimensions allow rapid penetration of the fixative. Large specimens should be rapidly transported to the lab to allow grossing (tissue slices can be prepared to allow proper fixation to occur).
Large specimens are left in fixative for an extended time prior to grossing. The center of the specimen may remain unfixed and the tissue can become markedly distorted.
![Expedite Large Specimen Fixation](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/csm_Step_09_toast-racked_heart_cd3017ef90.jpg?itok=gz8yL34T)
Avoid Unnecessary Delays
No unnecessary delays – specimen reaches lab in minimum time.
Specimens are sometimes delayed, specimen transport has a low priority and is not well organized.
![Avoid Unnecessary Delays](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/csm_Step_10_Specimen_delivery_18e82272ee.jpg?itok=WIj1Cadk)
Handle Specimens Gently
Specimens handled gently – fragile specimens remain intact.
Specimens handled roughly – delicate friable specimens can be damaged.
![Handle specimens gently](/sites/default/files/styles/720_tablet_portrait_fallback/public/media_image-file/2021-01/csm_Step_11_Fragments_from_frialble_tissue_b892787155.jpg?itok=K0JDeScK)
About the presenter
![Geoffrey Rolls](/sites/default/files/styles/square/public/media_image-file/2020-12/Geoffrey-Rolls.jpg.webp?itok=nrXJdZVf)
Geoffrey Rolls is a Histology Consultant with decades of experience in the field. He is a former Senior Lecturer in histopathology in the Department of Laboratory Medicine, RMIT University in Melbourne, Australia.
Related Content
Die Inhalte des Knowledge Pathway von Leica Biosystems unterliegen den Nutzungsbedingungen der Website von Leica Biosystems, die hier eingesehen werden können: Rechtlicher Hinweis. Der Inhalt, einschließlich der Webinare, Schulungspräsentationen und ähnlicher Materialien, soll allgemeine Informationen zu bestimmten Themen liefern, die für medizinische Fachkräfte von Interesse sind. Er soll explizit nicht der medizinischen, behördlichen oder rechtlichen Beratung dienen und kann diese auch nicht ersetzen. Die Ansichten und Meinungen, die in Inhalten Dritter zum Ausdruck gebracht werden, spiegeln die persönlichen Auffassungen der Sprecher/Autoren wider und decken sich nicht notwendigerweise mit denen von Leica Biosystems, seinen Mitarbeitern oder Vertretern. Jegliche in den Inhalten enthaltene Links, die auf Quellen oder Inhalte Dritter verweisen, werden lediglich aus Gründen Ihrer Annehmlichkeit zur Verfügung gestellt.
Vor dem Gebrauch sollten die Produktinformationen, Beilagen und Bedienungsanleitungen der jeweiligen Medikamente und Geräte konsultiert werden.
Copyright © 2025 Leica Biosystems division of Leica Microsystems, Inc. and its Leica Biosystems affiliates. All rights reserved. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH.